High-flow cementitious grout for post-tensioning ducts. Zero chloride, ASTM C939/EN 447 compliant, non-shrink with anti-corrosion. Ideal for bridges, wind farms & nuclear plants. It consists of two components, a component for normal weather use and b component for cold weather construction.
Keywords:
Post-Tensioning Grout (PT Grout)
Duct Grout
Cementitious Grout for Prestressed Tendons
Bridge Tendon Grouting Material
Product Introduction
Full Duct Filling with Anti-Corrosion Protection;Good fluidity, no water secretion, no delamination; Full early strength and micro-expansion of slurry; One-time slurry construction, dense slurry in the pipe without porosity; Pre-stressing steel does not rust, and concrete bond is strong.
Bridge tendon grouting: Full duct filling for corrosion protection in highway/railway bridges
Nuclear power plants: Low permeability + chloride-free for safety-critical structures
Offshore wind farms: Saltwater-resistant protection for turbine foundations
High-rise buildings: Prestressed slab/beam duct grouting
1. Before use, carry out trial mixing to determine the best ratio, H-60A (H-60) recommended mixing amount of 10%.
2. Mixing: should be used at a speed of not less than 1000rpm/min high-speed mechanical mixer mixing mixing order is: first add water to the appropriate scale, open the mixer, uniformly add the mortar agent, and then uniformly add the cement; all the powder to join the end of the mixing and then stir for 3 to 5 minutes to press the mortar.
3. Grouting: grouting as soon as possible after mixing, should take the usual grouting methods to ensure continuous pouring.
4. Protective measures: Wear protective gloves and goggles during construction.
5. Cleaning:Clean all construction tools and equipment with water.
Product Parameters
Test item | H-60B | H-60A |
Water-cement ratio (%) | ≤0.33 | 0.26 ~0.28 |
Setting time (h) Initial condensation Final condensation | ≥4 ≤24 | ≥5 ≤24 |
Water discharge rate (%) | 0 | 0 |
Fluidity (25°C) Initial flow 30min flow 60min flow | 14~22 ≤30 - | 10~17 10~20 10~25 |
Pressure discharge rate (%) | ≤2.5 | ≤2.0 |
Packed in composite kraft paper bag, net weight 40kg/bag, A component is:40kg/bag, B component is:40kg/bag.shelf life is 6 months.
It should be stored in dry and ventilated room, with the bag tightly closed, pay attention to moisture-proof and anti-freezing.